. Origin import compressor with more stable performance.
. Microcomputer control, nonvolatile operation, memory-maintained function, digital temperature display.
. Direct-cooling refrigeration of evaporator coil plus pre-embedded refrigeration evaporator can prevent pipeline corrosion due to long-term use.
. Optional padlock ensures sample safety.
. Height-adjustable shelf divides the chamber into different sized storage spaces, which maximizes storage efficiency in case of long-term use.
. Painted steel made exterior and interior, beautiful and durable, rust-proof and corrosion-proof.
· MDF-548D's double chambers with independent temperature control enables different temperature settings and separate defrosting without sample moving-out.
. Nonvolatile memory, memory-maintained function, digital temperature display.
. In case of power failure, press "Buzzer" button, display of current temperature will last for 5 seconds. Once the power is recovered, the freezer will return to the settings (nonvolatile memory temperature, alarm settings, etc.) before power failure.
Parameter |
|
External Dimensions (WxD x H) | 616×770×1806mm |
Internal Dimensions (Wx D xH) | 472×614×1262mm |
Volume | 369L |
Net weight | 128Kg |
Performance |
|
Temperature Setting Range | -20℃~-30℃ |
Ambient Temperature | 5℃~35℃ |
Cyclic curve |
|
Noise Level (db) | 48db |
Refrigeration |
|
Refrigeration System | Fixed frequency |
Refrigeration Mmethod | Direct coolling |
Evaporator | Coil type |
Compressors | GMCC |
Refrigerant | R404A |
Insulation Material | PUF |
Insulation Thickness | 72mm |
Defrost | Munaul defrost |
Construction |
|
Exterior Material | Painted steel |
Interior Material | |
Outer Doors/Lid | 1 |
Outer Door Lock | Mechanical lock |
Shelves | Hard steel wire polyester vinyl coating |
Max. Load - Per Shelf | 30kg |
Access Port | 1 |
Access Port Position | back |
Access Port Diameter | 30mm |
Casters | 4 |
Controller |
|
Controller | Microprocessor |
Display | Digital |
Adjustment accuracy | 0.1℃ |
Temperature Sensor | NTC 10K |
Alarm(V=VisualAlarm,B=Buzzer Alarm,R= Remote Alarm) |
|
Cabinet temperature alarm | V-B-R |
Sensor alarm | |
Power failure alarm | |
Remote alarm output | R |
Electrical |
|
Power Supply(V) | 220~240V |
Frequency(Hz) | 50Hz |
Heat dissipation value | 1108kj/h |
Rated input power | 308VA |
Power consumption(KWh/24h) | 4.0kWh/24h |
Communication systems |
|
Standard port | RS485, USB |
Optional port | —— |
Standard Accessories |
|
Accessories | —— |
Options |
|
Optional | —— |
Quality Management System |
|
Certification | CE,ISO13485, ISO9001, ISO14001 |