. By sensing the set temperature and the real-time change of the temperature in the internal,the compressor running power is adjusted to achieve continuous and stable control of the temperature in the internal.
. In stable movement,reduce the running power of the compressor, the temperature in the internal is more uniform, improve the energy-saving effect.
. When the machine starts or opens the door to put the sample, improve the running power of the compressor,cool down faster,and the sample is more safe.
· VIP Vacuum insulation technology optimized U-Vacua vacuum insulation technology material+polyurethane foam insulation layer design, the overall thermal insulation effect reaches a new height, and the thermal insulation performance is increased by 20%.
. The use of hydrocarbon refrigerant cascade refrigeration technology,cooling quickly after opening the door,to ensure the safety of samples.
· The unique expansion tank design can effectively stabilize the system pressure,maintain the normal operation of the compressor and extend the service life when the system pressure changes rapidly due to the change of ambient temperature or other reasons.
. Password protection of core parameters to avoid unnecessary losses caused by misoperation.
.. The use of pure natural refrigerant, fluorine-free environmental protection, greatly reduced charge, lower than the national 150g standard, safe and reliable.
. The power consumption of the whole machine is reduced by 20%, and the power consumption required for a single cryo tube is reduced to a new level.
Parameter |
|
External Dimensions (WxD x H) | 1180×875×1990 mm |
Internal Dimensions (Wx D xH) | 1040×600×1380 mm |
Volume | 861L |
Net weight | 350kg |
2 Inch Box capacity | 616 |
2ML Vial capacity | 61, 600 |
Performance |
|
Temperature Setting Range | -50~-86℃ |
Ambient Temperature | 10~30℃ |
Cyclic curve |
|
Noise Level (db) | 53.3 dB [A] |
Refrigeration |
|
Refrigeration System | Cascade-type |
Evaporator | Coil tube |
Compressors | Toshiba compressor×2(Variable frequency) |
Refrigerant | High temp:R290 low temp:R170 |
Insulation Material | PUF+ VIP |
Insulation Thickness | 70 mm |
Defrost | Manual |
Vaccum Release Port | Automatic |
Construction |
|
Exterior Material | Painted steel |
Interior Material | |
Outer Doors/Lid | Foam door×1 |
Outer Door Lock | Mechanical lock×1 |
Inner Doors/Lid | ABS foam×2 |
Shelves | 3×SUS304 |
Shelves deminsion | W1021×D543 mm |
Max. Load - Per Shelf | 50kg/pc |
Access Port | 2 |
Access Port Position | Back×1,bottom×1 |
Access Port Diameter | 17mm |
Casters | 4 |
Controller |
|
Controller | Microprocessor |
Display | Digital display |
Adjustment accuracy | 0.1℃ |
Temperature Sensor | Pt1000 and NTC thermistor sensors |
Alarm(V=VisualAlarm,B=Buzzer Alarm,R= Remote Alarm) |
|
Cabinet temperature alarm | V-B-R |
Door open alarm | |
Sensor alarm | |
Power failure alarm | |
Remote alarm output | |
Ampient temperature alarm | |
Compressor alarm | |
Remote Alarm Contacts( NO/NC) | —— |
Electrical |
|
Power Supply(V) | 220~240V |
Frequency(Hz) | 50/60Hz |
Rated input power | 1300W |
Power consumption(KWh/24h) | 11.1KWh/24h (AT: 25℃, Setpiont: -80℃, unloaded) |
Heat Dissipation value(Unloaded/Loaded | —— |
Communication systems |
|
Standard port | RS485 |
Optional port | —— |
Standard Accessories |
|
Accessories | Keys (1 set), defrost shovel (1 piece) |
Options |
|
Optional | Liquid CO2 back up, Inventory rack |
Quality Management System |
|
Certification | CE, ISO13485, ISO9001, ISO14001 |
CATALOGS
REQUEST A QUOTE
SERVICE HOTLINE
+86 18640846040